OMRON
E52-CA2GVY 1M     E52-IC2GVY 1M E52-CA2GVY 2M           E52-IC2GVY 2M E52-CA2GVY 4M           E52-IC2GVY 4M E52-CA2GVY 8M      E52-IC2GVY 8M   E52-CA1GTY 1M          E52-IC1GTY 1M E52-CA1GTY 2ME52-IC1GTY 2M E52-CA1GTY 4M E52-IC1GTY 4M E52-CA1GTY 8M      E52-IC1GTY 8M  E52-P2GSY 1M E52-P2GSY 2M E52-P2GSY 4M E52-P2GSY 8M  E52-P10GRY 2M E52-P10GRY 4M  E52-P10GPY 2M E52-P10GPY 4M  E52-CA20AY-1 D=4.6 2M E52-CA20AY-1 D=6 2M E52-CA20AY-1 D=8 2M  E52-P20AY-1 D=4.6 2M E52-P20AY-1 D=6 2M E52-P20AY-1 D=8 2M   E52-P5AY-40 2M E52-P5AY-40 4M E52-P5AY-40 6M E52-P5AY-40 8M    E52-CA20C-N-6 D=6.4 L2=150 E52-CA35C-N-6 D=6.4 L2=300 E52-CA50C-N-6 D=6.4 L2=450 E52-CA75C-N-6 D=6.4 L2=700  E52-P20C-N-6 D=6.4 L2=150 E52-P35C-N-6 D=6.4 L2=300 E52-P50C-N-6 D=6.4 L2=450 E52-P75C-N-6 D=6.4 L2=700  E52-CA20AY-7 D=3.2 2M E52-CA20AY-7 D=4.8 2M E52-CA20AY-7 D=6.4 2M E52-CA20AY-7 D=8.0 2M  E52-P20AY-7 D=4.8 2M E52-P20AY-7 D=6.4 2M  E52-CA1DY-40 M6 1M E52-CA1DY-40 M6 2M E52-CA1DY-40 M6 4M  E52-CA1GTY-14 1M E52-CA1GTY-14 2M E52-CA1GTY-14 4M E52-CA1GTY-14 8M
Temperature Sensor (Exclusive Models)
Specifications:
Thermocouples
Thermocouples for Molding Machines
E52-CA2GVY, E52-IC2GVY
| Lead wire length (m) | Element type: K (CA) | Element type: J (IC) | 
| Model | 
| 1 | E52-CA2GVY 1M | E52-IC2GVY 1M | 
| 2 | E52-CA2GVY 2M | E52-IC2GVY 2M | 
| 4 | E52-CA2GVY 4M | E52-IC2GVY 4M | 
| 8 | E52-CA2GVY 8M | E52-IC2GVY 8M | 
Thermocouples with Crimp Terminal
E52-CA1GTY, E52-IC1GTY
| Lead wire length (m) | Element type: K (CA) | Element type: J (IC) | 
| Model | 
| 1 | E52-CA1GTY 1M | E52-IC1GTY 1M | 
| 2 | E52-CA1GTY 2M | E52-IC1GTY 2M | 
| 4 | E52-CA1GTY 4M | E52-IC1GTY 4M | 
| 8 | E52-CA1GTY 8M | E52-IC1GTY 8M | 
Platinum Resistance Thermometers
Platinum Resistance Thermometers for Surface Temperature Measurement
E52-P2GSY
| Lead wire length (m) | Model | 
| 1 | E52-P2GSY 1M | 
| 2 | E52-P2GSY 2M | 
| 4 | E52-P2GSY 4M | 
| 8 | E52-P2GSY 8M | 
Platinum Resistance Thermometers for Room Temperature Measurement
E52-P10GRY
| Lead wire length (m) | Model | 
| 2 | E52-P10GRY 2M | 
| 4 | E52-P10GRY 4M | 
Waterproof Platinum Resistance Thermometers
E52-P10GPY
| Lead wire length (m) | Model | 
| 2 | E52-P10GPY 2M | 
| 4 | E52-P10GPY 4M | 
Corrosion-resistant Models with Fluororesin-covered Protective Tubing
Thermocouples
Exposed-lead Models
E52-CA20AY-1
| Model | Protective tubing
 length L (cm)
 | Protective tubing
 diameter
 | Sleeve diameter (mm) Sleeve length (mm)
 | Covering thickness
 (mm)
 | Lead wire length (m)
 | 
| E52-CA20AY-1 D=4.6 2M | 20 | D = 4.6 | d = 8 l = 55
 | 0.7 | 0.5 | 
| E52-CA20AY-1 D=6 2M | D = 6.0 | 0.6 | 
| E52-CA20AY-1 D=8 2M | D = 8.0 | d = 11 l = 55
 | 0.8 | 
Platinum Measurement
Exposed-lead Models
E52-P20AY-1
| Model | Protective tubing
 length L (cm)
 | Protective tubing
 diameter
 | Sleeve diameter (mm)
 | Covering thickness (mm)
 | Lead wire length (m)
 | 
| E52-P20AY-1 D=4.6 2M | 20 | D = 4.6 | d = 8 | 0.7 | 2 | 
| E52-P20AY-1 D=6 2M | D = 6.0 | d = 8 | 0.6 | 
| E52-P20AY-1 D=8 2M | D = 8.0 | d = 8 | 0.8 | 
FEP-molded Models (Completely Waterproof)
E52-P5AY-40
| Model | Lead wire length (m) | 
| E52-P5AY-40 2M | 2 | 
| E52-P5AY-40 4M | 4 | 
| E52-P5AY-40 6M | 6 | 
| E52-P5AY-40 8M | 8 | 
Pressure-resistant Explosion-proof (IICT6) Models
Thermocouples
Enclosed-terminal Models
E52-CA[][]C-N-6
| Model | Protective tubing length L (cm)
 | Protective tubing diameter
 | L2 (mm) | 
| E52-CA20C-N-6 D=6.4 L2=150 | 20 | D = 6.4 | 150 | 
| E52-CA35C-N-6 D=6.4 L2=300 | 35 | D = 6.4 | 300 | 
| E52-CA50C-N-6 D=6.4 L2=450 | 50 | D = 6.4 | 450 | 
| E52-CA75C-N-6 D=6.4 L2=700 | 75 | D = 6.4 | 700 | 
Platinum Resistance Thermometers for Surface Temperature Measurement
Enclosed-terminal Models
E52-P[][]C-N-6
| Model | Protective tubing length L (cm)
 | Protective tubing diameter
 | L2 (mm) | 
| E52-P20C-N-6 D=6.4 L2=150 | 20 | D = 6.4 | 150 | 
| E52-P35C-N-6 D=6.4 L2=300 | 35 | D = 6.4 | 300 | 
| E52-P50C-N-6 D=6.4 L2=450 | 50 | D = 6.4 | 450 | 
| E52-P75C-N-6 D=6.4 L2=700 | 75 | D = 6.4 | 700 | 
Double-element Models
Thermocouple
Exposed-lead Models
E52-CA20AY-7
| Model | Protective tubing
 length L (cm)
 | Protective tubing
 diameter
 | Sleeve diameter (mm)
 | Permissible Temperature (°C)
 | Lead wire length (m)
 | 
| E52-CA20AY-7 D=3.2 2M | 20 | D = 3.2 | d = 11 | 750 | 2 | 
| E52-CA20AY-7 D=4.8 2M | D = 4.8 | d = 11 | 800 | 2 | 
| E52-CA20AY-7 D=6.4 2M | D = 6.4 | d = 11 | 800 | 2 | 
| E52-CA20AY-7 D=8.0 2M | D = 8.0 | d = 11 | 900 | 2 | 
Platinum Resistance Thermometers
Exposed-lead Models
E52-P20AY-7
| Model | Protective tubing length L (cm)
 | Protective tubing diameter
 | Lead wire length (m) | 
| E52-P20AY-7 D=4.8 2M | 20 | D = 4.8 | 2 | 
| E52-P20AY-7 D=6.4 2M | D = 6.4 | 2 | 
Enclosed-terminal Models
E52-P20C-N-7
| Model | Protective tubing length L (cm) | Protective tubing diameter | 
| E52-P20C-N-7 D=4.8 | 20 | D = 4.8 | 
| E52-P20C-N-7 D=6.4 | 20 | D = 6.4 | 
Silicone-covered Lead Wires Models
Thermocouples
Exposed-lead Models with Screws
E52-CA1DY-40
| Model | Screw pitch | Lead wire length (m) | 
| E52-CA1DY-40 M6 1M | M6 (P=1.0) | 1 | 
| E52-CA1DY-40 M6 2M | M6 (P=1.0) | 2 | 
| E52-CA1DY-40 M6 4M | M6 (P=1.0) | 4 | 
Thermocouples with Crimp Terminal
E52-CA1GTY-14
| Model | Lead wire length (m) | 
| E52-CA1GTY-14 1M | 1 | 
| E52-CA1GTY-14 2M | 2 | 
| E52-CA1GTY-14 4M | 4 | 
| E52-CA1GTY-14 8M | 8 |