| Model | LR-ZB100CP | 
| Type | Distance based laser sensor | 
| Shape | Rectangular | 
| Output | PNP | 
| Cable connection | M8 connector, 4-pin | 
| Detectable distance | 35 to 100 mm (650 to 0)*1 | 
| Standard detectable deviation | 35 to 50 mm: 1.5 mm50 to 100 mm: 3 mm
 | 
| Display resolution | 2 (0.2 mm) | 
| Spot diameter | Approx. 2 × 1 mm at 100 mm | 
| Response time | 1.5 ms / 10 ms / 50 ms selectable | 
| Light source | Type | Red laser (660 nm) | 
| Laser class | Class 1 laser product (IEC60825-1, FDA (CDRH) Part1040.10*2)
 | 
| Function | Indicator | 3-digit 7-segment display (red),output indicator (yellow),
 DATUM indicator (orange),
 1 spot indicator (green)
 | 
| Timer | OFF/ON delay/OFF delay/One-shot | 
| Rating | Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS | 
| Power consumption | 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12V) | 
| Specifications | Control output | PNP Open collector, Applied voltage 30 VDC or less, Control current 100 mA or less,
 Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA
 | 
| Protection circuit | Protection against reverse power connection, output overcurrent, output surge, reverse output connection | 
| Output operation | Light-ON / Dark-ON selectable | 
| External input | Input time calibration: 35 ms or more ON, 35 ms or more OFFLaser emission stop: 2 ms or more ON, 20 ms or more OFF
 Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less
 | 
| Environmental resistance | Enclosure rating | IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 | 
| Insulation resistance | 20 MΩ or more (500 VDC) | 
| Ambient light | Incandescent lamp: 4,000 lux or lessSunlight: 8,000 lux or less*4
 | 
| Ambient temperature | -10 to +50 °C (No freezing) | 
| Storage temperature | -25 to +75 °C (No freezing) | 
| Relative humidity | 35 to 85 % RH (No condensation) | 
| Withstand voltage | 1,000 VAC, 50/60 Hz, 1 min | 
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | 
| Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | 
| Material | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, Packing/Connector ring: FKM
 | 
| Accessories | Instruction Manual,Certification/Identification label (FDA)
 | 
| Weight | Approx. 55 g | 
| *1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
 *3 Have passed resistance tests with cleaning agents from multiple manufactures.
 *4 When the response time is 10 ms
 |