Model  | GP-M010  | 
Rated pressure  | -0.1 to +1 MPa (-1 to +10 bar)  | 
Possible display range  | -0.210 to +1.110 MPa (-2.10 to +11.10 bar)  | 
Zero-cut pressure value  | ±0.5% of F.S.  | 
Burst pressure  | 15 MPa (150 bar)  | 
Display resolution  | 0.001 MPa (0.01 bar)  | 
Fluid type  | Gas or liquid that will not corrode the liquid contact part  | 
Type of pressure  | Gage pressure  | 
Precision  | ±1.0% of F.S. or less*1  | 
Repeatability  | ±0.3% of F.S. or less*2  | 
Temperature characteristics  | ±0.6% of F.S./10°C  | 
Connection diameter  | G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)  | 
Box rotation angle  | Maximum 330°  | 
Medium temperature  | -20 to +100°C (no freezing/condensation)*3  | 
Power supply voltage  | 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS  | 
Current consumption  | 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4  | 
Display method  | 4 column, digital LED, red/Vertical inversion display possible  | 
Operation display light  | Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)  | 
Hysteresis  | During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) During window mode: fixed (0.5% of F.S.)  | 
Response  | Control output  | Selectable from 3 to 5000 ms  | 
Analogue output  | As above + 2 ms (90% response)  | 
Output  | Output 1 control output  | NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable  | 
Output 2 replacement type  | Control output  | 
Analogue output  | 4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5  | 
Environmental resistance  | Enclosure rating  | IP67  | 
Pressure resistance  | 4 MPa (40 bar)  | 
Ambient temperature  | -20 to +80 °C (No freezing and no condensation)  | 
Relative humidity  | 35 to 85 % RH (No condensation)  | 
Vibration resistance  | IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes)  | 
Shock resistance  | IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction)  | 
Material properties  | Port/diaphragm  | Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM  | 
Other parts  | Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.  | 
Applicable cable  | M12 connector 4 pin  | 
Weight  | Approx. 150 g  | 
*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C. *2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition. *3 When the temperature of the piping exceeds 80°C, do not connect the cable. *4 Consumption current including output is 0.6 A and under. *5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω  |