KYOWA
NTB-50C Strain Unit
Medium Speed Network Terminal Box
Specifications:
Terminal Block  | One-touch type  | 
Channels  | 4  | 
Measuring Targets  | Strain gages Strain-gage transducers  | 
Compatible Bridge Resistance  | Quarter-bridge 120 Ω (2-wire, 3-wire) Half-bridge, Full-bridge 120 to 1000 Ω  | 
Gage Factor  | 2.00 fixed  | 
Bridge Excitation  | 2 VDC ±1%  | 
Check Functions  | Cable disconnection check  | 
TEDS  | Reads information from TEDS-installed sensors. Channel name writing (If the manufacturer's ID is Kyowa)  | 
Measuring Range, Resolution, Range Accuracy  | Measuring range: 30 k ×10-6 strain Resolution: 0.1 ×10-6 strain Range accuracy: ±0.1%FS
  Measuring range: 300 k ×10-6 strain Resolution: 1 ×10-6 strain Range accuracy: ±0.1%FS  | 
Response Frequencies  | DC to 100 Hz (Deviation +1 dB, -3 dB)  | 
Dimensions  | 152.2 W × 6.1 H × 45 D mm (Excluding protrusions)  | 
Weight  | Approx. 85 g  | 
Compliance  | Directive 2014/30/EU (EMC) Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS)  |